Home
Products
Counterflow closed cooling tower
Compound flow closed cooling tower
Compound flow double inlet air closed cooling tower
Cross-flow closed cooling tower
Dry and Wet Combined Cooling Tower
Evaporative Air Cooler
Evaporative condenser
Air cooler
About Us
Company Profile
Honor
Enterprise Style
Application
Oil smelting
Hardening & annealing
Chemical chemistry
Metallurgical
Casting & forging
Refrigeration air conditioning
Equipment Manufacturing
3D Show
News
Company News
Industry News
Contact Us
Customer Message
中文版
English
11 Jul,2024
What are the reasons that affect the cooling effect of the closed cooling tower?
The closed cooling tower reduces the waste of water resources and achieves the effect of energy saving and emission reduction. At the same time, the device also has many problems. For example, the cooling effect of closed cooling tower is not ideal, which is the problem we need to pay attention!
Precautions for Preventing Freeze Damage in Cross-Flow Closed Cooling Towers
Oasis Ice Peak: As winter approaches, we need to pay attention to freeze protection for our crossflow closed cooling towers! Our crossflow cooling towers are designed and selected based on the higher wet-bulb temperatures typical of summer conditions. However, during seasons when wet-bulb temperatures aren’t as high—especially in the cold winter months—their cooling capacity actually becomes excessive.
How can a closed cooling tower be protected from freezing?
1. Operating a closed-circuit cooling tower below 0°C may lead to freezing of the fill material and air inlet windows, depending on your设定 for the chilled water outlet temperature. It is generally recommended to maintain an outlet water temperature of no lower than 10°C during winter. However, if lower temperatures are beneficial for operation, ensure that the system is run within this reduced range.
How to winterize a closed cooling tower?
As winter approaches, closed-circuit cooling towers, like our other equipment, must take the necessary measures to successfully get through the winter, ensure that there are no problems, play a normal role, and escort production.
What kind of water is used for closed cooling tower circulation?
Closed cooling towers, due to their fully enclosed circulation, have no evaporation, no consumption, no scaling, and no freezing. Generally, they use pure water circulation to prevent scaling. In winter, antifreeze can be used to avoid freezing hazards caused by short-term shutdowns. Antifreeze: Please prepare an appropriate amount of antifreeze according to the local minimum temperature. Pay attention to adding corrosion inhibitors and defoamers to prevent corrosion of carbon steel parts in the system and reduce foam generation during circulation.
Preparation before operation of cross-flow cooling tower!
1. Remove foreign objects from the air inlet. 2. Ensure there is sufficient clearance between the tail of the fan and the air duct to prevent damage during operation. 3. After completing the above checks, intermittently start the switch to check whether the fan is operating correctly and whether there are abnormal noises or vibrations. 4. Clean the debris from the hot water pan and the inside of the tower.